Analysis of Several Problems in Calibration of Pressure Calibration Table

Analysis of several common problems in pressure calibration table calibration:
The device that detects the spring hammer in the pressure calibration table will become a calibration device. Because there is no corresponding calibration procedure, a calibration certificate should be issued, and the calibration certificate should specify the measurement uncertainty. The "measurement standard assessment specification" requires "N-repeat measurement times, N should be as large as possible, generally not less than 10. If the repetitive introduction of the uncertainty component is not the main measurement uncertainty in the verification or calibration results Component, which allows to reduce the number of repeated measurements appropriately, but at least N>=6" should be satisfied. However, the use of the calibration device of the pressure calibration table emphasizes that “the impact element should be turned to different positions after each operation. The average value of the three readings on the calibration device can be used as the actual value of the impact energy of the measured spring hammer.” Therefore, the number of repeated measurements is insufficient.
Domestic and foreign production of the pressure calibration table spring hammer calibration device impact kinetic energy measured value using the dial pointer readings, due to the size of the dial and the diameter of the pointer caused the reading error is too large. There are two reasons for this: (1) Large division values. Because the impact kinetic energy of the spring hammer of the pressure checkbench is very small, it is difficult to achieve a small division value by conducting a small-scale 2J split on the disk by using the principle of potential energy. At present, the PDL company's domestic sales of the pressure calibration table spring hammer calibration device has a division value of 0.02J, scale line spacing of about 1MM, a few companies in the country production of pressure calibration table spring hammer calibration device indexing value 0.01J, tick spacing is less than 1MM. Taking a 0.14J spring impactor as an example, the accuracy of the calibration device is calculated as 3%, and its index value should be 0.004J. It is difficult to achieve the internal subdivision scale line on the 1MM pitch of the dial. (2) The pointer diameter greatly affects the reading. The calibration device manufactured at home and abroad uses a 0.7MM piano wire as a pointer, and the pointer of 0.7MM occupies 2/3 space of 1MM between two scale lines, resulting in a large error in estimation. Even if the scale is subdivided between the marks with a pitch of only 1 mm, the indexing value is increased. However, due to the effect of the 0.7MM indicator, the small value of the indexing is also invalid, and the estimation error is still large.
Through the above analysis, the spring hammer calibration device in the pressure calibration table can not meet the calibration of all the spring hammers. At the same time, there are no uniform calibration standards for the measurement institutions throughout the country, so the calibration methods and calibration devices are different. Therefore, in order to improve product quality and strengthen measurement management, the device has a uniform calibration standard across the country, and it is very important to develop a scientific and effective calibration device for pressure calibration tables.

Fuel Quick Connector with double seal ring radial seal structure, rubber modified by O - ring, mainly for fluid and the physical, chemical properties of custom, prevent aging, corrosion, swelling; O - ring have intermediate spacer ring separated, two sealing rings of the corresponding event space, the rubber matrix bonding does not occur, the external O-ring using synthetic rubber, enhanced mechanical properties, prevent air aging. Sealing ring and a spacer ring through the outer ring of the elastic bayonet device firmly fixed in the shell, does not produce seal off and shift phenomenon produced. Greatly ensure the safety of the seal.

The working environment of the fast fuel joint is not too many constraints. It is mainly through air, fuel, oil, oil and gas and other media, can work in the case of about 10bar over pressure. With regard to working temperature, the fuel fast coupling can be within the engine area at a temperature of about ~+110 in the short time of the -40 degree within the engine area (about half an hour)..

Fuel Line Quick Connector

Fuel Quick Connector,Auto Quick Connector,Quick Connect Fittings

Linhai Shinyfly Auto Parts Co.,Ltd. , https://www.chinashinyfly.com